Created At

Jun 19, 2022

Last Update

Mar 14, 2023

Platforms

HC 3 Lite, Z-box Hub, Yubii Home Pro, Yubii Home, Venture WISE, HC 3

Views

5033

Download

431

Type Quick App

This QuickApp gets your energy consumption and production data from Tibber Live. 
This QuickApp can be used in combination with the Tibber Monitor to get the Tibber Prices. 
Based on the Fibaro WebSockets/GraphQL demo by Peter Gebruers 

 

If you use Tibber for your Energy Panel, you can use this Tibber Live QuickApp for your energy consumption and production combined with the Tibber Monitor QuickApp to provide the Energy Panel with the hourly prices. 

 

 

 

Main device with positive or negative actual power consumption

 

Child devices are available for:

  • power (Actual consumption with maxPower in log text)
  • powerProduction (Actual production with maxPowerProduction in log text)
  • accumulatedConsumption (Todays consumption, also child device for the Energy Panel)
  • accumulatedProduction (Todays production)
  • accumulatedCost (Todays cost)
  • lastMeterConsumption (Total consumption)
  • lastMeterProduction (Total production)
  • voltagePhase1
  • voltagePhase2
  • voltagePhase3
  • currentL1
  • currentL2
  • currentL3

Available information: 

  • power (Consumption at the moment (Watt))
  • maxPower (Peak consumption since midnight (Watt))
  • powerProduction (Net production (A-) at the moment (Watt))
  • maxPowerProduction (Max net production since midnight (Watt))
  • accumulatedConsumption (kWh consumed since midnight)
  • accumulatedProduction (net kWh produced since midnight)
  • accumulatedCost (Accumulated cost since midnight; requires active Tibber power deal)
  • currency (Currency of displayed cost; requires active Tibber power deal)
  • lastMeterConsumption (Last meter active import register state (kWh))
  • lastMeterProduction (Last meter active export register state (kWh))
  • voltagePhase1 (Voltage on phase 1) *
  • voltagePhase2 (Voltage on phase 2) *
  • voltagePhase3 (Voltage on phase 3) *
  • currentL1 (Current on L1) *
  • currentL2 (Current on L2) *
  • currentL3 (Current on L3) *
  • accumulatedConsumptionLastHour (kWh consumed since since last hour shift)
  • accumulatedProductionLastHour (net kWh produced since last hour shift)
  • accumulatedReward (Accumulated reward since midnight; requires active Tibber power deal)
  • minPower (Min consumption since midnight (Watt))
  • averagePower (Average consumption since midnight (Watt))
  • powerReactive (Reactive consumption (Q+) at the moment (kVAr)) *
  • powerProductionReactive (Net reactive production (Q-) at the moment (kVAr)) *
  • minPowerProduction (Min net production since midnight (Watt))
  • powerFactor (Power factor (active power / apparent power)) *
  • signalStrength (Device signal strength (Pulse - dB; Watty - percent)) *
  • timestamp (Timestamp when usage occurred)

* on Kaifa and Aidon meters the value is not part of every HAN data frame therefore the value is null at timestamps with second value other than 0, 10, 20, 30, 40, 50. There can be other deviations based on concrete meter firmware. In this QuickApp "null" values are replaced by their previous values. 

 

To communicate with the API you need to acquire a OAuth access token and pass this along with every request passed to the server.
A Personal Access Token give you access to your data and your data only. 
This is ideal for DIY people that want to leverage the Tibber platform to extend the smartness of their home. 
Such a token can be acquired here: https://developer.tibber.com

 

When creating your access token or OAuth client you’ll be asked which scopes you want the access token to be associated with. 
These scopes tells the API which data and operations the client is allowed to perform on the user’s behalf. 
The scopes your app requires depend on the type of data it is trying to request. 
If you for example need access to user information you add the USER scope. 
If information about the user's homes is needed you add the appropriate HOME scopes.
If you have more than one home in your subscription, you need to fill in your home number the change between your homes. 


If the Tibber server disconnects the webSocket, the QuickApp wil do a re-connect for the amount in the QuickApp variable reconnect. 
If the re-connect fails for that amount, there will be a timeout for the seconds in the QuickApp variable timeout. 

 

Use this QuickApp at your own risk. You are responsible for ensuring that the information provided via this QuickApp do not contain errors. 
Tibber is a registered trademark being the property of TIBBER. TIBBER reserves all rights to the registered trademarks.
Information which is published on TIBBER’s websites belongs to TIBBER or is used with the permission of the rights holder. 
Making of copies, presentations, distribution, display or any other transfer of the information on the website to the public is, except for strictly private use, prohibited unless done with the consent of TIBBER. 
Published material on dedicated TIBBER press websites, intended for public use, is exempt from the consent requirement.
Also see: https://tibber.com/en/legal-notice

 

Guide Communicating with the Tibber API: https://developer.tibber.com/docs/guides/calling-api

Tibber API Explorer: https://developer.tibber.com/explorer

Tibber gitHub: https://github.com/tibber

Tibber SDK NET: https://github.com/tibber/Tibber.SDK.NET/tree/master/src/Tibber.Sdk

Fibaro webSocket manual: https://manuals.fibaro.com/knowledge-base-browse/hc3-quick-apps-websocket-client/

Fibaro Forum - Headers in webSocket: https://forum.fibaro.com/topic/60307-added-support-for-headers-in-websocket-connections-any-documentation

WebSocket++ Documentation: https://docs.websocketpp.org

GraphQL over WebSocket Protocol: https://github.com/enisdenjo/graphql-ws/blob/master/PROTOCOL.md

GraphQL query language: https://spec.graphql.org/June2018/#sec-Language

 

Version 3.0 (8th March 2023)

  • Removed Tibber old Websocket code
  • Prepared, not enabled: Check home.features.realTimeConsumptionEnabled has a true value always before reconnecting
  • Prepared, not enabled: Added button to disconnect or re-connect the Tibber webSocket
  • Prepared: Added quickapp variable homeNr (most of the time 1) to be able to check the response realTimeConsumptionEnabled

Version 2.3 (beta 8th December 2022)

  • Improved the 60 seconds interval child devices update, it now never skips a beat
  • Added translation for English (en), Dutch (nl), Swedish (se), Norwegian (no)
  • Changed the json response for the debugLevel=4 Offline Simulation mode, the date/time format was wrong
  • Added random (jitter) reconnection handleDisconnected and handleError between 10 and 15 seconds
  • Added random (jitter) reconnection interval handleDisconnected and handleError plus between 1 and 10 seconds
  • Added exponential backoff (increasing delay) between each timeout. The increase is limited to 10 times the value in the quickapp reconnect variable. 

 

Variables (mandatory and created automatically): 

  • token = Authorization token (see the Tibber website: https://developer.tibber.com)

  • homeId = Tibber Home ID (see the Tibber website: https://developer.tibber.com)

  • homeNr = Tibber home (nodes) number if you have more than one home (default = 1)

  • language = Preferred language (default = en) (supported languages are English (en), Swedisch (se), Norwegian (no) and Dutch (nl))

  • reconnect = Amount of re-connects after disconnect from Tibber server (default = 10)

  • timeout = Pause after maximum amount of re-connects (default = 300 seconds)

  • debugLevel = Number (1=some, 2=few, 3=all, 4=Offline Simulation Mode, 5=Live Test Mode) (default = 1)

Fibaro Firmware:

Minimal version 5.111.48 (beta)

How to install: 

  1. Open the Configuration Interface
  2. Go to Settings > Devices
  3. Click  +
  4. Choose Other Device
  5. Choose Upload File
  6. Choose file from your computer with .fqa

 

24 Comments,  Want to add comment please login
4bc52c28cd381c52d003f70be91ddd42

Perfect addition to the Tibber Monitor QA!

04801fd12b48c36cbcdf5af0b140e42d

Thanks you Jens. Indeed the Tibber Monitor quickapp for prices (future) and the Tibber Live quickapp for energy usage (now and history)

764bfb42bc8c572f4459254668d98087

Brilliant! I found a small error. Volts and amps have been swapped in the energy panel. If you are going to update once, I could wish to have the last hour consumption as a separate child device. I am so happy you have done this work!

04801fd12b48c36cbcdf5af0b140e42d

Thanks Morten. In the next version there are extra child devices for last hour consumption and production. It is being tested right now. What do you mean with volt and amps being swapped?

764bfb42bc8c572f4459254668d98087

Thank you! In the Tibber Live panel (top picture on this side) Voltage: L1: 233 - L2: 235 - L3: 235 Amp Ampere: L1: 4.46 - L2: 1.31 - L3: 0.96 Volt

© 2024. Nice-Polska Sp. z o.o.Privacy policyTerms & ConditionsFeedback