FIBARO Choice

Created At

Apr 26, 2020

Last Update

Sep 30, 2022

Platforms

HC 3 Lite, Z-box Hub, Yubii Home Pro, Yubii Home, Venture WISE, HC 3

Views

26916

Download

4157

Type Quick App

QuickApp module to integrate of Netatmo climate devices.

It has support for Main module, Outdoor modules and Indoor modules, Rain gauge and Smart anemometer. It creates child devices (Temperature Sensors, Humidity Sensors, CO2 Sensors, Pressure Sensors, Noise sensors, Rain and Wind sensors) automatically based on information gathered from Netatmo API.

To use it you need to import attached .fqa file into HC3 and provide tokens (access_token and refresh_token) from Netatmo API. To generate these tokens please visit site https://gsmart.pl/netatmo/ and follow instructions.

Other variables:

  • battery_allone - can be "true" or "false" - to choose between battery interface on dedicated child devices or directly on child devices

These values are in "Variables" tab on imported device. Click on Pencil, fill data for corresponding variables and click "Save". After that you need to create child devices. To do that you have to go to the "Edit & Preview" tab and click on "Get Devices" button.

If tokens are ok after few seconds you should have created all linked devices for found Netatmo modules. Values for these devices are refreshed every 10s after values updated in Netatmo cloud (more or less at 10min period). QA also has a "Get Measurements" button to manually refresh data.

Important note: 5.030 or newer firmware version on HC3 is needed.

Changelog:

v2.6 - 09/2022 (GSmart)

  • changed authorization method with Netatmo API (required by Netatmo servers)

v2.5.1 - 03/2021 (GSmart+Lazer)

  • FIX QuickApp hang after HC3's upgrade to 5.063 firmware
  • Added Czech translation (thanks to petrkl12)
  • Minor fixes & enhancements

v2.5 - 07/2020 (Lazer)

  • Fix QuickApp crash in case weather station has no additional module

v2.4 - 07/2020 (Lazer)

  • Add variable to choose between battery interface on dedicated child devices or directly on child devices

v2.3 - 06/2020 (Lazer)

  • New device types (Rain, Wind, Gust)
  • Add battery levels monitoring (use dedicated child devices)
  • Add alive module monitoring (use Netatmo reachable property to make Fibaro devices appearing dead in the interface)
  • Optimized 10 minutes query interval 10s after Netatmo cloud update
  • Minor fixes & enhancements

v2.2 - 06/2020 (GSmart)

  • FIX: prevent crash when we doesn't get any data from Netatmo API
  • Added status info on main QA device

v2.1 - 05/2020 (GSmart)

  • Added support for unit conversion, eg. km/h to m/s
  • Further enhancements in code

v2.0 - 04/2020 (GSmart)

  • Completely redesigned
  • Getting all data in one request to Netatmo API

v1.1 - 04/2020 (GSmart)

  • Added support for Wind and Rain modules

v1.0 - 04/2020 (GSmart)

  • Initial release
  • Supported devices: Base station, Outdoor module, Indoor module

 

75 Comments,  Want to add comment please login
75a1e020e0f7b2d126f7a3803017d9fb

Bardzo dobra aplikacja. Samo się dzieje Polecam

C60b1fba39552766fcf9b61af71af954

Polecam

2d1c7118074f08f4d4a68cf5fca128ce

[14:20:02] [ERROR] [QUICKAPP48]: QuickApp crashed[16.05.2020] [14:20:02] [ERROR] [QUICKAPP48]: line: 128 attempt to concatenate a nil value (field 'module_name') What to do?

2d1c7118074f08f4d4a68cf5fca128ce

Thanks to Gsmart, the problem was that i have access to a friends Netatmo, and the main module was unamed. I deleted my access and it works right away.

74e1ee5ac66cdf397775322f3d63953f

Hi, thank you very much for this QuickApp. I made an updated version, based on your code, with few enhancements : - get battery levels - use Netatmo reachable property to make Fibaro devices appearing dead in the interface Do you agree that I share my modified version ? With full credits off course.