Created At

Nov 19, 2017

Last Update

Nov 05, 2018

Platforms

HC 2

Views

6501

Download

351

FUNCTIONS

The DSCengine VD plugin can send and receive events to and from your DSC Power Series alarm on to global variables and VD labels to be used as triggers in scenes. The plugin can handle all partitions in the DSC Power Series Alarm.

 

Trigger that exist as of this version is:

  • breach/restore/tamper/alarm/fault of all zones
  • AC power status in your house
  • Panel battery status
  • Alarm ARMING status
  • Partiton is in alarm
  • And much more….

 

The DSCengine integration VD also can:

  • Send codes to arm the DSC alarm to the status you wish. AWAY, STAY, ZERO-ENTRY-AWAY, ZERO-ENTRY-STAY
  • ARM and  DISARM the alarm remotely
  • You will see what user that armed or disarmed the DSC alarm
  • It will handle the system even if you have more than one partition
  • A lot more is logged than what there are scene triggers for
  • It can send _very_ detailed logs to a syslog server if you set up one. 
  • Send arbitrary key pad events. See example section in the attached PDF

It has 4 auto created sub devices when starting the service:

  • A presentation device that shows arming status, live zone status as well as AC power status and more
  • A Partition1 management device that shows partition status. It also give the possibility to ARM, DISARM, ARM STAY plus have panic buttons.
  • A Partition 2 device (optional. Created if a variable is set) that is similar to the Partition 1 device except no panic buttons.
  • A log device. Auto created. This show a history log

  

INSTALLATION

  • Described in HC2_DSCengine-QuickGuide.pdf 

 

ADDITIONAL DEVICES 


This integration VD requires one or the other of the following:

  • An EnvisaLink card inserted into your DSC Power Series alarm
  • Global Cache iTach Flex with Flex Link RS232 Serial cable + DSC IT-100 serial card

 

PACKAGE CONTENT

 

File name SHA1 checksum
HC2_DSCengine-3.5.lua 355efc3a59c4b529015ba0af08bfbf575aeee52e
HC2_DSCengine-3.5.vfib 35c2edb2076491135cb77b76b4ff470cdc0c1c1f
HC2_DSCengine-QuickGuide.pdf 4cc8d2b15c475d0fbf9a9aec86b1d514b071637e
HC2_DSCengine-release_notes.txt 0f6f8416465401e22e37e6dca36fac26af0e5eb3
HC2_DSCengine-LICENSE.txt 741e7dbd3d0f2f17edcc1b03ab8db68659ee33e2

 

And much more…

Hope you like it ! 

18 Comments,  Want to add comment please login
3bee437fa56baad1cfa1b312d4fa323a

@Geoff Clow Neo has, at least at the moment, a non publicly open API. I can probably have access to it by filling in an NDA. But it wont be possible to implement it in LUA on HC2 as the script code is open for all to see. This plugin works for the DSC Power Series alarms. /Peo

Cc64bdb1c88e1914682a9a47eb086f11

Hi Peo Will your plugin with with Neo series DSC alarms? I have a HS2032. (http://dsc.com/alarm-security-products/HS2032%20-%20PowerSeries%20Neo%20Control%20Panels/2442) Cheers, Geoff.

5f98e40a1ea09993bb7b731caa130689

Hi, I can't download the file, it says network error. Could you please check.

3bee437fa56baad1cfa1b312d4fa323a

@Alejandro I don't know. I wrote this plugin is for HC2 only. Why? Because I do not know the limitations of a HCL and the specs for HCL. I only have a HC2. For this plugin to work, you must be able to paste in ".lua" code in a VD or import the ".vfib". Then when starting, sub devices will be auto created and configured along with a few global and predef variables. If that is possible I am afraid you have to ask somebody else with HCL knowledge. Or just test...

C8dccdf84ed2389e6dc273ff331943ac

Hello, first of all thank the VD, this VD works in HCL? or just work on the HC2 controller? Greetings.