Created At
Jul 07, 2025
Created By Albert W.
GoodWe hybrid PV inverters integration for FIBARO Home Center 3 and NICE Yubii Home
Created At
Jul 07, 2025
Last Update
Feb 27, 2026
Platforms
HC 3 Lite, Z-box Hub, Yubii Home Pro, Yubii Home, Venture WISE, HC 3
Views
2189
Download
146
GoodWe hybrid PV inverters integration with FIBARO Home Center 3 series and NICE Yubii Home hubs, via the Modbus protocol.
This integration is published in form of encrypted QuickApp device. File attached below is a trial (demo) version that runs for 7 days after installation.
The full version has no time limitation and is distributed as an encrypted QuickApp, released for single FIBARO Home Center or Nice Yubii hub with serial number provided by the buyer.
Cost of full version is 100 Euro without VAT tax (for EU companies with valid EU VAT ID we can use 0% VAT tax for others 23% VAT tax will be applied, so total is 123 Euro to pay).
Cost is per one FIBARO Home Center / NICE Yubii controller.
Please contact us if you need USD calculations.
Payment option: bank wire transfer (SEPA/Swift), Paypal
Contact and more details: smarthome @ hdev.pl
Seller and developer: Human Devices company, VAT EU: PL8942392501
More at www.hdev.pl/en
More about GoodWe PV devices at: https://en.goodwe.com/energy-storage-solutions
The integration was tested with GoodWe GW-15K-ET + battery (modbus TCP via Wifi-LAN Kit 2.0 Dongle wired by LAN)
GoodWe inverters support the Modbus TCP protocol, so integration can be started immediately after connecting the device to the home network via a WiFi or LAN cable and enabling Modbus TCP protocol at inverter’s settings.
The connection works locally, without usage of a cloud or the Internet. Data is read in real time, refreshed few times per minute, without limits and delays.
As an alternative, GoodWe devices also support Modbus RTU protocol on the RS-485 serial connector. For such connection you need an additional Modbus RTU-TCP Gateway, which must be purchased and installed yourself. Such gateway can also support other devices with the Modbus RTU protocol in parallel. For Modbus RTU option please contact us for more details.
Note: Modbus TCP works only for LAN connections (no WiFi), and when WIFI/LAN Kit 2.0 or WIFI/LAN Kit 2.0 (Cyber Security Version) dongle is used. These dongles is not compatible with older models and firmware of PV inverters. Compatibility info file is attached.
Note 1: Minimum required battery SOC parameter, described below, limits charging/discharging battery for each of above strategies.
Note 2: the inverter has a number of additional configuration parameters that affect the operation of above strategies. The parameters can limit the charging/discharging power, specify the minimum battery SOC, limit the maximum power of battery charging from the grid, and many others.
QuickApp adds the following set of meters and other child devices to the system:
These child devices can be used in Energy Panel configuration, and in scenes.
More information about available options and configuration of all devices can be found in the document available for download below.
The QuickApp is a demo version that works for 7 days after installing.
Fqax file shall be imported to your Home Center / Yubii Home hub at administration panel (accessed via Web browser): menu Settings, section Devices, button Add, tab Other Device, command Upload File.
NOTE: At the time of QuickApp installation, the FIBARO HomeCenter or Yubii Home hub must be registered on the owner's FibaroID account and must be connected to the Internet (this is a general requirement for the installation of encrypted QuickApps).

ETA, EHA models are just a submodels in ET/EH series. They have same specification for modbus communication, so this integration shall work. Integration uses Modbus TCP so you do not have to use extra equipment. You can download Demo of the QuickApp, enable Modbus TCP in configuration of your inverter, and test it.

Does the GoodWe ETA Hybrid 12 kW work with this three-phase model

Official statement from Goodwe support was "LAN only". But at some forums users confirms that Modbus TCP works via WiFi too. We cannot verify that. It can also depend on dongle's firmware version or hardware revision.

If I understand correctly, I will need a LAN connection for integration to Homecenter; WLAN is impossible?
Updated list of compatible models: ET PLUS+ Serie ET PLUS+ (16A) Serie ET (15-30 kW) Serie BT Series EH Serie EH PLUS+ Serie ES Serie ES G2 Serie SBP Serie SBP G2 Serie BH Serie ESA Serie EM Serie ETC Serie BTC Serie