Created At

Jul 01, 2020

Last Update

Jul 02, 2020

Platforms

HC 2

Views

296

Download

29

This plugin allows to control AC unit power, operation mode, target temperature, fan speed and flow direction.

Works with any Wi-Fi compatible Daikin AC unit.

To use this plugin simply write IP address of your AC unit and 80 port in vitual device settings.

IP address can be found in settings of AC unit in official application.

2 Comments,  Want to add comment please login
2ec9cf248853f58cad9b3f4409534d2d

Thanks for the excellent work.

Eb8cd43e0f4af5182d652e3075ed4c20

Thanks for the excellent work. I wanted to apply the plugin to my Australian version of Daikin Airbase BRP15B61 and some settings were different and i wanted to share it with anyone facing with similar issues. - downloading the status: http://192.168.xx.xx/skyfi/aircon/get_control_info - setting the control: http://192.168.1.76/skyfi/aircon/set_control_info?pow=1&mode=1&stemp=22&dt1=21&dt2=21&dt3=21&f_rate=5&dfr0=1&dfr1=1&dfr2=5&dfr3=1&f_airside=0&airside0=0&airside1=0&airside2=0&airside3=0&f_auto=0&auto0=0&auto1=0&auto2=1&auto3=0&f_dir=0&dfd0=0&dfd1=0&dfd2=0&dfd3=0&dfd7=0&filter_sign_info=0&cent=0&en_cent=0&remo=2 the control set is different in my version: [DEBUG] 02:48:12: a[1]=ret=OK [DEBUG] 02:48:12: a[2]=pow=1 [DEBUG] 02:48:12: a[3]=mode=1 [DEBUG] 02:48:12: a[4]=stemp=23 [DEBUG] 02:48:12: a[5]=dt1=23 [DEBUG] 02:48:12: a[6]=dt2=21 [DEBUG] 02:48:12: a[7]=dt3=21 [DEBUG] 02:48:12: a[8]=f_rate=1 [DEBUG] 02:48:12: a[9]=dfr0=1 [DEBUG] 02:48:12: a[10]=dfr1=1 [DEBUG] 02:48:12: a[11]=dfr2=5 [DEBUG] 02:48:12: a[12]=dfr3=1 [DEBUG] 02:48:12: a[13]=f_airside=0 [DEBUG] 02:48:12: a[14]=airside0=0 [DEBUG] 02:48:12: a[15]=airside1=0 [DEBUG] 02:48:12: a[16]=airside2=0 [DEBUG] 02:48:12: a[17]=airside3=0 [DEBUG] 02:48:12: a[18]=f_auto=0 [DEBUG] 02:48:12: a[19]=auto0=0 [DEBUG] 02:48:12: a[20]=auto1=0 [DEBUG] 02:48:12: a[21]=auto2=1 [DEBUG] 02:48:12: a[22]=auto3=0 [DEBUG] 02:48:12: a[23]=f_dir=0 [DEBUG] 02:48:12: a[24]=dfd0=0 [DEBUG] 02:48:12: a[25]=dfd1=0 [DEBUG] 02:48:12: a[26]=dfd2=0 [DEBUG] 02:48:12: a[27]=dfd3=0 [DEBUG] 02:48:12: a[28]=dfd7=0 [DEBUG] 02:48:12: a[29]=filter_sign_info=0 [DEBUG] 02:48:12: a[30]=cent=0 [DEBUG] 02:48:12: a[31]=en_cent=0 [DEBUG] 02:48:12: a[32]=remo=2 the minimum parameter set is longer: param = a[2] .. "&" .. a[3] .. "&" .. a[4] .. "&" .. a[8] .. "&" .. a[13] .. "&" .. a[19] .. "&" .. a[23] and the mode parameters are different: if (mode == 3 or mode == 4 or mode == 5) then mode_name = "АUТО" elseif mode == 7 then mode_name = "Dry" elseif mode == 2 then mode_name = "Cooling" elseif mode == 1 then mode_name = "Heating" elseif mode == 0 then mode_name = "Fan" there are separate command for Auto/normal fan mode: a[18], f_auto=0 for normal and 1 for auto fan mode. I hope it is useful, thank you for all the great work,

Load more comments